KAA31474AAB_STM-NGSOK2门机资料.doc

上传人:11****ws 文档编号:3655063 上传时间:2019-07-03 格式:DOC 页数:68 大小:1.17MB
下载 相关 举报
KAA31474AAB_STM-NGSOK2门机资料.doc_第1页
第1页 / 共68页
KAA31474AAB_STM-NGSOK2门机资料.doc_第2页
第2页 / 共68页
KAA31474AAB_STM-NGSOK2门机资料.doc_第3页
第3页 / 共68页
KAA31474AAB_STM-NGSOK2门机资料.doc_第4页
第4页 / 共68页
KAA31474AAB_STM-NGSOK2门机资料.doc_第5页
第5页 / 共68页
点击查看更多>>
资源描述

1、Service Tool Users GuideNGSOK2Service Tool ManualSoftware Basic Data No: KAA31474AAB_STMSCN: KAA31474AABPage: 1/68Date: 2012-07-20Engineering CenterKoreaCopyright 2012, OTIS Elevator Co. No part of this document may be copied or reproduced in any form or by any means without the prior written consen

2、t of OTIS.NGSOK2Service Tool Users GuideAuthorization Date : 2012. 07. 20Running on PCB: KAA26800ACA or laterSoftware Version: KAA31474AABDocument Revision:Date Author Comment2011-03-14 Hansoo Shim Original Document2012-07-20 Hansoo Shim Updated for KAA31474AABService Tool Users GuideNGSOK2Service T

3、ool ManualSoftware Basic Data No: KAA31474AAB_STMSCN: KAA31474AABPage: 2/68Date: 2012-07-20Engineering CenterKoreaTable of Contents1 Introduction.41.1 Power On.51.2 Key Function Description .52 Software Overview.72.1 Local and Remote Service tool .72.1.1 Local SVT connection.72.1.2 Remote SVT connec

4、tion .72.2 Menu Overview .82.2.1 Monitoring Functions (M-3-1).92.2.2 Test Functions (M-3-2) .92.2.3 Setup (M-3-3).92.2.4 Run (M-3-4).92.2.5 Engineering (M-3-5).102.3 Key-Function Overview.102.4 Access restriction for SVT Menu .102.4.1 Require SVC mode to access menu .122.4.2 Remote SVT inaccessible

5、Menu .123 Function Menus .143.1 Monitoring Functions (M-3-1) .143.1.1 Status (M-3-1-1) .153.1.2 Input (M-3-1-2).173.1.3 Output (M-3-1-3).193.1.4 Runs: Run Time display (M-3-1-4) .203.1.5 Part: Display Software Version (M-3-1-5) .203.1.6 SysConfig (M-3-1-6).213.1.7 Statistics (M-3-1-7) .233.2 TEST (M

6、-3-2).243.2.1 Event log (M-3-2-1) .243.2.2 History log (M-3-2-2).243.2.3 Clear log (M-3-2-3) .263.3 Setup (M-3-3).273.3.1 Inst: Installation (M-3-3-1).273.3.1.1 CONFIGOPERATOR (M-3-3-1-1) .273.3.1.2 LEARN-RUN (M-3-3-1-2) .293.3.1.3 MASS: MOVING MASS INPUT (M-3-3-1-3).323.3.2 DoorTim: Adjust Door Tim

7、e (M-3-3-2) .333.3.3 Def.: Set Default (M-3-3-4).353.3.4 InfChk: Interface check (M-3-3-5).373.3.5 System Reset (M-3-3-6).383.3.6 Parameters (M-3-3-7).393.3.6.1 PROF1: PROFILE 1 PARAMETER SETUP (M-3-3-7-1) .393.3.6.2 PROF2: PROFILE 2 PARAMETER SETUP (M-3-3-7-2) .40Service Tool Users GuideNGSOK2Servi

8、ce Tool ManualSoftware Basic Data No: KAA31474AAB_STMSCN: KAA31474AABPage: 3/68Date: 2012-07-20Engineering CenterKorea3.3.6.3 SYSTM: SYSTEM PARAMETER SETUP (M-3-3-7-3).403.3.6.4 CNTRL: CONTROL PARAMETER SETUP (M-3-3-7-4) .403.3.6.5 SELECT: PROFILE SELECT (M-3-3-7-5) .403.3.6.6 PROF3: PROFILE 3 PARAM

9、ETER SETUP (M-3-3-7-6) .413.3.6.7 PROF4: PROFILE 4 PARAMETER SETUP (M-3-3-7-7) .413.3.6.8 FIRPRF: FIREMAN SVC PHASE 2 PROFILE PARAMETER SETUP (M-3-3-7-8).413.4 Run (M-3-4).423.4.1 Single: Single Door run (M-3-4-1) .423.4.2 Cont.: Cycle door run (M-3-4-2).433.4.3 Off (M-3-4-3) .433.5 Engineering Menu

10、 (M-3-5).443.5.1 BusV the lower part of the key is blue. To activate the white function on any key, just press the marked button. To activate the blue function on any key, use the combination of keys. First press SHIFT (the unmarked blue button on the lower left of the keypad), and then press the in

11、tended key. For example, if the GO ON/GO BACK key is pressed, the GO ON function occurs. If the SHIFT key as well as the GO ON/GO BACK key is pressed, then the GO BACK function occurs.The connection to the NGSOK2 Door Controller is done by connecting SVT line into port P11 on the SPMDCB2Figure 1-1 M

12、echanical Design of Service ToolSELF TEST-OK- MECS MODEOTIS Service Tool8MODULE 7 95FUNCTION 4 6GO ON0 CLEAR2SET 1 3OFF GO BACK ENTERON UP DOWNDISP IN SEL OUTDISP STATEENT CALL TESTSHIFT KEY16 Characters2 line displayService Tool Users GuideNGSOK2Service Tool ManualSoftware Basic Data No: KAA31474AA

13、B_STMSCN: KAA31474AABPage: 5/68Date: 2012-07-20Engineering CenterKorea1.1 Power OnAfter power on, the Service Tool performs a self-test. After the successful test the serial communication to the SPMDCB2 is checked. Depending on the result of this test, a message is displayed.To enter the menu system

14、 the key, Module has to be pressed. To check the software version of the Service Tool, press the SHIFT KEY and then Module.Figure 1-2 Self test sequence1.2 Key Function DescriptionThe following symbols are used throughout the manual:ON first press SHIFT and then ONSELFTESTIN PROGRESSSELFTESTOK - MEC

15、S MODESELFTESTOK - MP2/3 MODEPower onSelf test passed;Communication established Self test passed;no communicationGO ON key GO ON to be pressedGOBACK first press SHIFT and then GOBACK1 key 1 to be pressed2 key 2 to be pressed3 key 3 to be pressedService Tool Users GuideNGSOK2Service Tool ManualSoftwa

16、re Basic Data No: KAA31474AAB_STMSCN: KAA31474AABPage: 6/68Date: 2012-07-20Engineering CenterKoreaUP first press SHIFT and then UPDOWN first press SHIFT and then DOWNENTER first press SHIFT and then ENTERCLEAR key CLEAR to be pressedThe numeric keys 1 thru 9 as a key to pressDIGITSEL OUT first press

17、 SHIFT and then SEL OUTService Tool Users GuideNGSOK2Service Tool ManualSoftware Basic Data No: KAA31474AAB_STMSCN: KAA31474AABPage: 7/68Date: 2012-07-20Engineering CenterKorea2 Software OverviewThe software for the Service Tool provides a menu system, which is organized as a tree structure. With th

18、e numeric keys and the keys MODULE, FUNCTION and SET you can easily move through the system. With the key CLEAR you can clear the most recently pressed key.2.1 Local and Remote Service tool2.1.1 Local SVT connectionAfter connecting the service tool to NGSOK2 directly, below display will be shown. To

19、 enter into sub menus, type 32.1.2 Remote SVT connectionIf Service tool is connected through other sub system (OCSS, MCSS) Remote connection, after pressing module key and then pressing key 3 and the below door selection main menu is displayed.OCSS=1 MCSS=2DCSS=3 DBSS=4DCSS #1 frontDCSS #2 altern3 k

20、ey 3 to be pressedSPMDCB2 SVT menuDCSS = 3Monitor=1 Test=2Setup=3 Run=43 key 3 to be pressedService Tool Users GuideNGSOK2Service Tool ManualSoftware Basic Data No: KAA31474AAB_STMSCN: KAA31474AABPage: 8/68Date: 2012-07-20Engineering CenterKorea2.2 Menu OverviewAll functions are arranged in groups t

21、o simplify selection of the desired function. After you have selected the module (i.e. subsystem) you can choose the type of function you want to perform.Each menu is arranged under a section heading with a list of related subheadings. Each subheading lists the key sequence. For example, M-3-1-1 mea

22、ns that you should press MODULE key, then the 3 key, then the 1 key, then the 1 key to monitor door status. M (MODULE) will always be the first key pushed.SPMDCB2 SVT menuDCSS = 3Monitor=1 Test=2 Setup=3Status=1Input=2Run=4Outp=3 Runs=4Part=5SysCfg=6Stat=7Log=1History=2Clear Log=3Inst=1DoorTim=2Def.

23、=4InfChk=5Reset=6Single=1Cont.=2Off=3ConfigOperator=1Learn=2Mass=3Engineering=5BusV&C=1IDQV=2DoorTime=3KE=4Parameters=7SetSimul=8PROF1=1PROF2=2SYSTM=3CNTRL=4SELECT=5PROF3=6PROF4=7FIRPRF=8ClearEEPROM=9Service Tool Users GuideNGSOK2Service Tool ManualSoftware Basic Data No: KAA31474AAB_STMSCN: KAA3147

24、4AABPage: 9/68Date: 2012-07-20Engineering CenterKorea2.2.1 Monitoring Functions (M-3-1)M-3-1-1 Status Status displayM-3-1-2 Input Discrete input displayM-3-1-3 Outp Discrete output and communication reporting signal displayM-3-1-4 Runs System run time and total cycle displayM-3-1-5 Part SCN and comp

25、ilation dateM-3-1-6 SysCfg Display system configuration(Interface, door id, etc)M-3-1-7 Stat Door movement statistics2.2.2 Test Functions (M-3-2)M-3-2-1 Log Display event log by event id orderM-3-2-2 History Display event log by occurrence orderM-3-2-3 Clear Log Clear event logs2.2.3 Setup (M-3-3)M-

26、3-3-1 Inst Install MenuM-3-3-1-1 ConfigOperator Operator configuration(interface, door id, deck id)M-3-3-1-2 Learn Perform learn runM-3-3-1-3 Mass Input moving massM-3-3-2 DoorTim Motion profile calculated by time specificationM-3-3-4 Def. Set default Parameters for door operator typeM-3-3-5 InfChk

27、Perform 3 wire check sequenceM-3-3-6 Reset Reset SystemM-3-3-7 Parameters Manual editing of parametersM-3-3-7-1 PROF1 Profile 1 parameter setupM-3-3-7-2 PROF2 Profile 2 parameter setupM-3-3-7-3 SYSTM System parameter setupM-3-3-7-4 CNTRL Motor parameter setupM-3-3-7-5 SELECT Profile selectM-3-3-7-6

28、PROF3 Profile 3 parameter setup M-3-3-7-7 PROF4 Profile 4 parameter setupM-3-3-7-8 FIRPRF Profile for Fireman SVC Phase 2 setupM-3-3-8 SetSimul Set Simulator Configuration(hidden)M-3-3-9 Clear EEPROM Clear EEPROM(hidden)2.2.4 Run (M-3-4)M-3-4-1 Single Single run testM-3-4-2 Cont. Continuous run test

29、M-3-4-3 Off Stop run testService Tool Users GuideNGSOK2Service Tool ManualSoftware Basic Data No: KAA31474AAB_STMSCN: KAA31474AABPage: 10/68Date: 2012-07-20Engineering CenterKorea2.2.5 Engineering (M-3-5)M-3-5-1 BusV&C Bus Voltage and current displayM-3-5-2 IDQV Motor torque current displayM-3-5-3 D

30、oorTime Door open/close time displayM-3-5-4 KE Display Kinetic energy2.3 Key-Function OverviewThe number of service tool input keys is 16 keys. Some keys have a second function (marked in blue color) which is activated by pressing SHIFT and then press the key with the desired function. Some keys hav

31、e special function by itself.MODULE:Guides to the top level menu, the NGSOK2 welcome message will be displayed. It will interrupt learn-run and wiring sequence check.FUNCTION:Guides to the second level menu. This key function will be inactive during wiring sequence check and learn-run.SET:Returns fr

32、om a Sub-menu to the Menu level of ownership. This key function will be inactive during wiring sequence check and learn-run.GO ON / GO BACK:Navigate through the next/previous menu page display or scroll the parameter list to next/previous item.CLEAR:Erase last entered value.ENTER:Press SHIFT and the

33、n ENTER. It indicates that the inputs are finished in parameter setting and selection is completed. SHIFT & 7:On main menu and sub menu, it toggles capability to edit hidden parameters.2.4 Access restriction for SVT MenuService Tool usage can be restricted according to the conditions for security and safety. There are 3 kinds of access restrictions.