水泥土搅拌桩复合地基计算书1确定单桩承载力(1)按确定桩体材料所提供的单桩承载特征值:水泥土搅拌桩(湿法)桩身强度折减系数,取=0.25R=fcuAp=0.25x2500x0.19625=122.7kN(2)按桩端、桩侧摩阻力计算单桩承载力:R=pLi+Apqp=1.57x(1.5x10+1.5x9.5+2.2x11+4.0x8+0.6x12)+0.4x0.19625x130=155.7 kN取R =122.7kN2.确定桩土面积置换率取桩间土承载力折减系数=0.5由公式fspk=m+(1-m)fsk=130kpa可得:m=0.139按m=0.14布桩。d=1180mm 实际布桩为1180mmx1140mm。3.软弱下卧层验算Es5/Es6=5100/4200=1.21,Z/b=13.7m/14m=0.97,取=0度,软弱下卧层顶面处的附加压力为Pz=Lb(Pk-Pc)/(b+2ztan)(L+2ztan)=14x47.6x(130-36.5)/14x46.7=93.5Kpa,Pc