DISTALRA桡骨远端 PPT课件.ppt

上传人:h**** 文档编号:192103 上传时间:2018-07-15 格式:PPT 页数:27 大小:3.17MB
下载 相关 举报
DISTALRA桡骨远端 PPT课件.ppt_第1页
第1页 / 共27页
DISTALRA桡骨远端 PPT课件.ppt_第2页
第2页 / 共27页
DISTALRA桡骨远端 PPT课件.ppt_第3页
第3页 / 共27页
DISTALRA桡骨远端 PPT课件.ppt_第4页
第4页 / 共27页
DISTALRA桡骨远端 PPT课件.ppt_第5页
第5页 / 共27页
点击查看更多>>
资源描述

1、AP view radiograph of an intraarticular distal radius fracture.,Lateral view radiograph of an intraarticular distal radius fracture.,BARE AREA,EPL,2mc,The bare area of the radius is identified.,A 5-mm incision is made over the bare area of the radius.,A fine clamp is used to dissect gently down to b

2、oneto avoid damage to neurologic and vascular structures.,Once the clamp is on bone, two Ragnell retractors are used to retract the tendons to either side of the radius. A small key elevator is used to clean an area of bone for the pin cannulas.,BONE,Bone is visualized at the base of the incision, c

3、onfirmingthat there is no danger to the superficial radial nerve orother structures.,A cannula system is used for drilling and half-pin placement.,After the hole is drilled, the inner cannula is removed and the pin is placed through the outer cannula.,To determine the location of the second pin, a p

4、in clamp is used.,After both proximal pins are placed, fluoroscopy confirms the appropriate length.,The distal pins are placed into the second metacarpal. The mark on the metacarpal indicates the first pin, placed near the base of the second metacarpal. The second pin is placed distal to this using

5、a pin clamp as a guide to its location.,The forearm after the two sets of pins are placed. The connecting rods are applied to the frame, then the initial reduction is performed.,The initial reduction is performed by flexing the elbow,slightly supinating the forearm and pulling gentle traction.,The f

6、rame is then tightened in this position andradiographs are obtained with 10 degrees ofangulation in each direction.,A small dorsal incision can be made for the percutaneous reduction of impacted fragments as well as for bone grafting.,A curved osteotome is used to elevate an impacted ulnar-sided fra

7、gment.,A curved osteotome is used to elevate an impacted ulnar-sided fragment.,Allograft bone or other bone graft substitute may be introduced into the dorsal defect at this point.,Clinical picture of the external fixator and percutaneous pin in place.It is important at this time to test that full flexion of the MP and IPjoints is possible, as well as motion of the thumb, confirming thatnone of the tendons are impinged and that there is not overdistractionof the carpus.,AP radiograph after fixation.,

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 重点行业资料库 > 医药卫生

Copyright © 2018-2021 Wenke99.com All rights reserved

工信部备案号浙ICP备20026746号-2  

公安局备案号:浙公网安备33038302330469号

本站为C2C交文档易平台,即用户上传的文档直接卖给下载用户,本站只是网络服务中间平台,所有原创文档下载所得归上传人所有,若您发现上传作品侵犯了您的权利,请立刻联系网站客服并提供证据,平台将在3个工作日内予以改正。